MMD-8KW SOLAR INVERTER/ CHARGER

Purpose
This manual describes the assembly, installation, operation and troubleshooting of this unit. Please read
this manual carefully before installations and operations. Keep this manual for future reference.
Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.

للحجز سجل بياناتك وهنتواصل معاك في أقرب وقت

الأسم كامل *
رقم الهاتف *
البريد الإلكتروني *
الدولة *
إترك ملحوظة إذا كان لديك

شارك على :

Facebook
Twitter
LinkedIn

الوصف

                                SPECIFICATIONS

Line Mode Specifications

MODEL 8KW
Input Voltage Waveform Sinusoidal (utility or generator)
Nominal Input Voltage 230Vac
Low Loss Voltage 170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage 180Vac±7V (UPS); 100Vac±7V (Appliances)
High Loss Voltage 280Vac±7V
High Loss Return Voltage 270Vac±7V
Max AC Input Voltage 300Vac
Max AC Input Current 60A
Max Output Current for 2nd output 40A
Nominal Input Frequency 50Hz / 60Hz (Auto detection)
Low Loss Frequency 40±1Hz
Low Loss Return Frequency 42±1Hz
High Loss Frequency 65±1Hz
High Loss Return Frequency 63±1Hz
Output Short Circuit Protection Line mode: Circuit Breaker (70A)Battery mode: Electronic Circuits
Efficiency (Line Mode) >95% (Rated R load, battery full charged)
Transfer Time 10ms typical (UPS); 20ms typical (Appliances)

 

Inverter Mode Specifications

MODEL 8KW
Rated Output Power 8000W
Output Voltage Waveform Pure Sine Wave
Output Voltage Regulation 230Vac±5%
Output Frequency 60Hz or 50Hz
Peak Efficiency 93%
Overload Protection 100ms@≥205% load; 5s@≥150% load; 10s@110%~150% load
Surge Capacity 2* rated power for 5 seconds
Optional 12V DC Output 12 VDC ± 7%, 100W
High DC Cut-off Voltage 66Vdc
Low DC Cut-off Voltage 44Vdc
Nominal DC Input Voltage 48Vdc
Cold Start Voltage 46.0Vdc
Low DC Warning Voltage @ load < 20% 46.0Vdc
Low DC Warning Voltage @ 20% ≤ load < 50% 42.8Vdc
Low DC Warning Voltage @ load ≥ 50% 40.4Vdc
Low DC Warning Return Voltage @ load < 20% 48.0Vdc
Low DC Warning Return Voltage @ 20% ≤ load < 50% 44.8Vdc
Low DC Warning Return Voltage @ load ≥ 50% 42.4Vdc
Low DC Cut-off Voltage @ load < 20% 44.0Vdc
Low DC Cut-off Voltage @ 20% ≤ load < 50% 40.8Vdc
Low DC Cut-off Voltage @ load ≥ 50% 38.4Vdc
High DC Recovery Voltage 64Vdc
High DC Cut-off Voltage 66Vdc
DC Voltage Accuracy +/-0.3V @ no load
THDV <5% for linear load, <10% for non-linear load @ nominal voltage
DC Offset ≤100mV

 

Charge Mode Specifications

 

 

MODEL 8KW
Utility Charging Mode
Charging Current (UPS) @ Nominal Input Voltage 120A
Bulk Charging Voltage – Flooded Battery 58.4Vdc
Bulk Charging Voltage – AGM / Gel Battery 56.4Vdc
Floating Charging Voltage 54Vdc
Overcharge Protection 66Vdc
Charging Algorithm 3-Step
Solar Input
Rated Power 8000W
Max. PV Array Open Circuit Voltage 500Vdc
PV Array MPPT Voltage Range 90Vdc ~ 450Vdc
Max. Input Current 27A x 2 (MAX 40A)
Max. Charging Current 120A
Start-up Voltage 80V +/- 5Vdc

 

General Specifications

MODEL 8KW
Safety Certification CE
Operating Temperature Range -10°C to 50°C
Storage Temperature -15°C ~ 60°C
Humidity 5% to 95% Relative Humidity (Non-condensing)
Dimension (DWH), mm 147.4 x 432.5 x 553.6
Net Weight, kg 18.4

Parallel Specifications

Max parallel numbers 6
Circulation Current under No Load Condition Max 2A
Power Unbalance Ratio <5% @ 100% Load
Parallel communication CAN
Transfer time in parallel mode Max 50ms
Parallel Kit YES